			| Model No. | Input Voltage Range | Rated Load | Maximum Outputs | MTBF (hours)
 | Operating Temp.
 | 
|---|
 | +5V | +12V | -12V | +5V | +12V | -12V | 
|---|
 | ACE-890A | AC | 85-265V | 10A | 2.5A | 0.5A | 12A | 4.0A | 1.0A | 268,000 | -20 - +70°C | 
|---|
 | ACE-890P | DC | 70-132V | 10A | 2.5A | 0.5A | 12A | 4.0A | 1.0A | 265,000 | -20 - +70°C | 
|---|
 | ACE-890C | DC | 36-72V | 10A | 2.5A | 0.5A | 12A | 4.0A | 1.0A | 269,000 | -20 - +70°C | 
|---|
 | ACE-890T | DC | 18-36V | 10A | 2.5A | 0.5A | 12A | 4.0A | 1.0A | 252,000 | -20 - +70°C | 
|---|
 | ACE-890V | DC | 9-16V | 9A | 2.5A | 0.5A | 12A | 4.0A | 1.0A | 245,000 | -20 - +70°C | 
|---|
 | The maximum output currents are based on 50°C operating temperature,
					   when the power supply is operated at 60-70°C, the maximum output
					   currents will be approximately 75-80% of above figures. |  |